Transmotor ApS

Transmotor ACG 75.800/AVRR 24-250 VDC

Transmotor generator ACG-75.800/AVRR 24-250 VDC

The ACG type brush less transistorized charging generator has been specially developed and designed for battery charging and/or DC power supply for small boats, e.g. fishing vessels, pleasure boats and the like, but can also be used for many other purposes where a DC voltage supply stable over variable speed is required.

Description:

The generators with electronic voltage controller are available as one- or three-phased AC power supply units for frequencies between 100 and 2000 Hz.

In ships the installation is suitable for operation by the ship's main engine where there is variable speed but can also be used in connection with an auxiliary machine for constant speed.

The installation consists of a generator which supplies a three-phased AC voltage and a rectifier/controller which rectifies the AC voltage to DC voltage and at the same time controls the DC output voltage.

During start-up the installation will self-generate voltage thus rendering the use of any outside supply point unnecessary.

Constant output voltage is maintained over speed variations at the ratio of one to four as well as load and surrounding temperature variations. Furthermore, the installation is current-limited, with or without time delay, depending on the use. This involves overload protection.

In addition, the installation is over voltage- and excess-temperature protected.

Installations with the same voltage requirements can operate in parallel in all conditions.

The installations, available with outputs from approx. 1 - 45 kW, meet the international classification standards

The rectifier/controller unit is made in a ventilated, drip-protected design intended for wall fitting. All parts are fitted in a painted steel box with perforated end pieces for natural cooling.

The top end piece is protected by a cap and a screw-flange is fitted at the bottom end. The main rectifier, which consists of black anodized dissipaters with press-fit type diodes, is assembled on a mounting plate inside the box.

The controller unit is mounted on the box lid and connected to the main rectifier unit by means of a terminal block. The entire controller unit is thus easily replaced by merely replacing the lid.

The controller unit consists of several units, i.e. a control unit, a transistor unit and a transformer unit (except 24 and 32 volt installations that do not contain a transformer unit).

The control unit of the controller consists of a U-shaped rack. Underneath there is a circuit board where the controller supply rectifier is mounted. In addition to the field fuse, the adjustable resistor for voltage adjustment, the terminal block for connection to the main rectifier and the terminal block for connection of the transistor and transformer unit, a circuit board base is also fitted on the upper surface of the rack as the weak-current components of the controller are fitted on a "plug-in" circuit which is protected by a cover plate.

ACG type brush less and transistorized charging and power supply installation. Generator 3 x 20-25 VAC, rectify to 24-30 VDC in connection with AVRR type rectifier/regulator.

The generator is a three-phased straight-pole generator in a ventilated drip-protected design IP21 with ball bearings, clear shaft end and B3 stand.

Lloyd's design, insulation class F.

24V

Part number generator

Generator type

AC output current

Output power in kW

Power input in kW

Full load working range in rpm

1/10 load at rpm

Recommended rectifier / regulator

Part number rectifier / regulator

DC output current AVRR

26040044

ACG-75

3x64

2.3

3.1

850-3400

675

AVRR-600B2

29751199

84

26050056

ACG-156

3x98

3.4

4.6

850-3400

675

AVRR-600B3

29751111

125

26040040

ACG-75

3x100

3.4

4.6

1250-5000

1000

AVRR-600B3

29751111

125

26040045

ACG-75

3x148

5.1

6.9

1900-5000

1500

AVRR-600B5

29751239

185

26050048

ACG-156

3x148

5.1

6.6

1250-5000

1000

AVRR-600B5

29751239

185

26060068

ACG-221

3x148

5.1

6.7

750-3000

575

AVRR-600B5

29751239

185

26050057

ACG-156

3x196

6.8

8.8

1700-5000

1400

AVRR-600B5

29751244

245

26060063

ACG-221

3x252

8.7

11.3

1250-5000

950

AVRR-600B8

29751135

315

26090061

ACG-501

3x280

9.8

12.5

700-3000

575

AVRR-601B8

29751246

350

26060071

ACG-221

3x378

12.5

16.2

1900-5000

1500

AVRR-600B10

29751245

450

26090056

ACG-501

3x360

12.5

15.9

1050-4200

850

AVRR-601B10

29751196

450

ACG type brush less and transistorized charging and power supply installation. Generator 3 x 88 VAC, rectify to 110-125 VDC in connection with AVRR type rectifier/regulator.

The generator is a three-phased straight-pole generator in a ventilated drip-protected design IP21 with ball bearings, clear shaft end and B3 stand.

Lloyd's design, insulation class F.

110V

Part number generator

Generator type

AC output current

Output power in kW

Power input in kW

Full load working range in rpm

1/10 load at rpm

Recommended rectifier / regulator

Part number rectifier / regulator

DC output current AVRR

26050054

ACG-156

3x37

5.3

6.6

1250-5000

1000

AVRR-606D1

29751214

46

26060069

ACG-221

3x38

5.3

6.7

750-3000

575

AVRR-607D1

29751252

46

26050058

ACG-156

3x48

6.9

8.8

1700-5000

1400

AVRR-606D2

29751219

60

26060066

ACG-221

3x64

8.9

11.3

1250-5000

950

AVRR-607D2

29751253

78

26090062

ACG-501

3x80

11.5

14.3

670-3000

550

AVRR-607D2

29751463

100

26060072

ACG-221

3x93

13.3

16.9

1900-5000

1500

AVRR-607D3

29751254

116

26090059

ACG-501

3x120

17.2

21.5

1000-4000

850

AVRR-607D3

29751499

150

26100023

ACG-800

3x152

22.0

28.0

815-3260

660

AVRR-607D5

29751473

192

26100025

ACG-800

3x180

26.0

33.0

950-3800

760

AVRR-607D5

29751222

226

26090064

ACG-501

3x192

27.6

34.0

1600-4200

1400

AVRR-607D5

29751223

240

26100021

ACG-800

3x230

33.0

41.0

1150-3800

920

AVRR-607D7

29751483

286

26100027

ACG-800

3x310

45.0

54.0

1450-3800

1160

AVRR-607D10

29751498

390

ACG type brush less and transistorized charging and power supply installation. Generator 3 x 175 VAC, rectify to 220-250 VDC in connection with AVRR type rectifier/regulator.

The generator is a three-phased straight-pole generator in a ventilated drip-protected design IP21 with ball bearings, clear shaft end and B3 stand.

Lloyd's design, insulation class F.

220V

Part number generator

Generator type

AC output current

Output power in kW

Power input in kW

Full load working range in rpm

1/10 load at rpm

Recommended rectifier / regulator

Part number rectifier / regulator

DC output current AVRR

26050055

ACG-156

3x19

5.3

6.6

1250-5000

1000

AVRR-606E1

29751226

23

26060070

ACG-221

3x19

5.3

6.7

750-3000

575

AVRR-607E1

29751256

23

26050059

ACG-156

3x24

6.9

8.8

1700-5000

1400

AVRR-606E1

29751404

30

26060067

ACG-221

3x32

8.9

11.3

1250-5000

950

AVRR-607E1

29751257

39

26090063

ACG-501

3x40

11.5

14.3

670-3000

550

AVRR-607E1

29751233

50

26060073

ACG-221

3x46

13.3

16.9

1900-5000

1500

AVRR-607E2

29751258

58

26090060

ACG-501

3x60

17.2

21.5

1000-4000

850

AVRR-607E2

29751234

75

26100024

ACG-800

3x76

22.0

28.0

815-3260

660

AVRR-607E3

29751464

96

26100026

ACG-800

3x90

26.0

33.0

950-3800

760

AVRR-607E3

29751235

113

26090065

ACG-501

3x96

27.6

34.0

1600-4200

1400

AVRR-607E3

29751236

120

26100022

ACG-800

3x115

33.0

41.0

1150-3800

920

AVRR-607E4

29751469

143

26100028

ACG-800

3x155

45.0

54.0

1450-3800

1160

AVRR-607E5

29751474

195

Upon request a certificate can be issued or a copy of a previously classified installation can be provided